Residential Laundry Chute
On a three-storey house, laundry moves down two flights several times a week. A chute turns that into one trip, at the bottom.
In the standard configuration gravity does the work — no fan, no motor, no control panel to fail. That is why the system suits a house that will stand for decades.
Soiled linen goes straight down from the bathroom o
r utility corridor instead of through bedrooms and stairs.
Sections are 300 mm across as standard, fixed to timber frame or concrete, with the bracket adjustable from 20 to 200 mm off the wall.
Sections, entries, bends and doors in stainless steel 304 or 316 — 316 where coastal air or treated water is a factor. The bore is smooth and free of projections for the full vertical run, with beaded ribs to hold the section round and the joints tight.
Sections join with quick clamps, so the run goes together without welding on site. Lengths are 1,200 mm, 600 mm, and adjustable sections of 100–600 mm to land on the floor height you actually have.
| Component | Function |
|---|---|
| Single / dual entry section | One door for a single-sided room; two doors where rooms sit on both sides of the shaft |
| Chute section, 1,200 mm | Main vertical run |
| Chute section, 600 mm | Main vertical run, short |
| Adjustable section, 100–600 mm | Lands the run on the actual floor-to-floor height |
| Bend 15° / 30° / 45° | Offsets around structure |
| Wall bracket | SS304 3.0 mm; 20–200 mm off the wall; timber frame or concrete |
| Quick clamp | Joins sections without site welding |
| Fire cut-off door | Base; 165°F (74°C) UL-listed fusible link |
You do not need to work out the split yourself — send the floor heights and we return a component list for the whole run.
Diameter runs 12" (300 mm), 14" (350 mm) or 16" (400 mm). Residential laundry chutes are normally 300–400 mm; anything above 400 mm is a commercial installation.
The laundry chute door is the part you touch. Side-hinged, powder-coated white as standard, stainless brushing available, and the face can be customised with a label or pattern. A sensor-operated door is available where a hands-free opening is preferred — that one does need power, and it is an upgrade rather than the standard fit.
Intake door sizes are set per project — send the opening you have and we confirm.
The section count follows the floor height, and this is the question buyers get wrong. The table below lists the combination for each floor-to-floor height from 2.4 m to 3.4 m. Send us the height and we confirm the exact bill.
| Floor height (SSL) | Chute entry | 1,200 mm section | Adjustable section |
|---|---|---|---|
| 2.4 m | 1 | 1 | 600 mm × 1 |
| 2.5 m | 1 | 1 | 700 mm × 1 |
| 2.6 m | 1 | 1 | 800 mm × 1 |
| 2.7 m | 1 | 1 | 900 mm × 1 |
| 2.8 m | 1 | 1 | 1,000 mm × 1 |
| 2.9 m | 1 | 1 | 1,100 mm × 1 |
| 3.0 m | — | — | confirmed per project |
| 3.1 m | 1 | 2 | — |
| 3.2 m | 1 | 2 | 200 mm × 1 |
| 3.3 m | 1 | 2 | 300 mm × 1 |
| 3.4 m | 1 | 2 | 400 mm × 1 |
The chute ends in a fire cut-off door held open by a 165°F (74°C) UL-listed fusible link. If fire reaches the collection area, the link melts and the door closes the chute.
That door is a fire device, not a shut-off. It is not designed to be used to close the chute in normal service — if you need the chute closed, close the intake door.
Eight steps, all in our own workshop — nothing is subcontracted and nothing is bought in finished.
Enquiry and drawing. You send floor heights, wall construction and intake points. We return a 3D drawing at the same scale as the actual site, so fit problems surface on paper rather than on site.
Laser cutting. Sheet is cut to pattern.
Bending. Sections are formed to diameter.
Welding. Vertical seams are welded rather than crimped, so the joint is watertight along the full length.
Polishing. The seam is dressed back to a smooth bore with no projection to catch linen.
Surface treatment. Brushed or mirror finish, with a protective film for transport.
Quality check. Bore, length and joint fit are checked against the drawing.
Packing. Sections are wrapped and marked for the floor they belong to.
The chute is a straight vertical run by default; bends at 15°, 30° and 45° handle the offsets a real house has. Every bend adds a snag point, so the design keeps them to a minimum.
And a laundry chute is not a rubbish chute. Linen and clothing go down it; household waste does not. The two need separate systems, and mixing them is how chutes get blocked.
Soiled linen is damp and carries detergent and body salts. Galvanised steel has a coating, and a coating that gets scratched inside a chute is a rust point nobody can reach. Stainless has no coating to wear off, and it holds up to humidity, mild acid and alkali.
The fire cut-off door at the base, held open by a 165°F (74°C) UL-listed fusible link. On intake doors for this residential range there is no fire rating — the door is a hinged access panel, not a fire assembly. If your project requires rated intake doors, tell us at enquiry and we will quote a different product for it.
Not if the bore is right and the run is straight. A 300 mm bore passes a full laundry bag without effort. Blocks come from undersized chutes, unnecessary bends, or rubbish going down a linen chute.
Yes, and this is a common retrofit. The bracketed sections are fixed inside a shaft or a cupboard run rather than cast into the structure, so an existing house can take a chute without major demolition. Send photographs of the available shaft and we will say what fits. In a finished wall, access and framing are the two things that decide the layout, and both are usually solvable.
Yes. Standard is powder-coated white, with stainless brushing available. The face can be marked with a label or pattern to match the room.
Both spellings get searched and both mean this product. The correct spelling is "chute"; "shoot" is the common misspelling. If you searched for a laundry shoot, you are in the right place.
15+ years manufacturing residential laundry chute systems. ISO 9001 certified. Spare parts held for ten years after supply.
Send the floor heights, the wall construction and the number of intake points. Quotations answered within 12 hours.